Loading...
D001158White — City Clerk Pink — Finance Dept. Canazy — Dept. Accounting Blue — Engineer Green — Contractor • No. o � 0 � :�� Date _ �— �-IL° CITY OF SAINT PAUL — OFFICE OF THE MAYOR ADMINISTRATIVE ORDER for CONTRACT CHANGE AGREEMENT N0. 3 ADMINISTRATIVE ORDER, Whereas, additions which proved to be neeessary to the Improvement described as ventilation of patients rooms and staff areas at the Public Health Center known as Contract �Y.-15205 , City Project No. 9446.00 , Envirornttental Systematics , Inc. , Contraeta, is composed of the following: 1.) Fabricate and install 32 ac3ditional duct fittings not shown on original plans but required by existing conditions ... $ 3,200.00 2.) Install a conc, curb around duct penetrations through the second floor . . . . . . . . . . . . . . . . . . . . . . . . $ 250.00 3,) Replace 29 (VAV caps) controllers so that changed air delivery system can be balanced . . . . . . . . . . . . . . . $ 4,577.50 \� TOTAL ADDITIONS . . . . . . . . . . . . . . . . . . . $ 8, 027. SO ORDERED, That the City of Saint Paul, through its Mayor, approves the foregoing additions made in ac- cordance with the specifications in the sum of 3$ SO , said amount to be added to the lump sum con- sideration named in the contract, known as contract �,- 15205 ,�d which amount is to be financed from: C95-3T026-0892-00000 • Stmunary Original Contract . . . . . . Change Order # 1 . . . . . . . Change Order #2 . . . . . . . This Change Order . . . . . . Revised Contract . . . . . . �—O�"is 9 � -�''? 19� � 19� z�l� is� $139,300.00 $ 1,194.00 $ 1,176.00 $ 8,027.50 $149,697.50 Envirormental Systematics, Inc. Contractor � of Adtninistrative Assistar�t to the Mayor !1 ' ; DEPLRTMEE:O�FRCFJCOUNCIL Dl/,,7/�,1 GREEN SHEE N_ 34964 CONTACf PERSON d PHONE INffIAUDATE INRIAVDATE � DEPHHTMENTDIRECTOR O CfIYCAUNdL Q1uck Ekstedt 266-9092 ���N CRYATfOfiNEY �CITYCLERK ST BE ON COUNCIL AGEN�A BY (DATE) MUYBER FOfl � BUDGET DIAECiO � FlN. & MGT. SERVICES DIR. ROUTING aMAYOR10FiASSISTANn I� � � OROEP b� TOTAL # OF SIGNATURE PAGES (CLIP ALL LOCATIONS FOH SICaNATURE) ACf10N FEW ES7ED: Signatures required for Change Order #3 for the ventilation of patient rooms and sta£f areas at the Public Health Center. RECOMMENDnTpNS: npprove (A) rn Reject (R) pEHSONAL SERVICE CONTRACTS MUST ANSWEii THE FOLLOWING QUESTIONS: _ PLqNNING COMMISSION _ qVIL SEFiVICE COMMISSION �� Has Mis person/firtn ever worked under a conhact for this departrnent? � _ CIB COMMRTEE YES NO . _ S7AFF 2. Has [his person/firm ever been a crty employee? — YES NO _ oIS7RiC7 COURT _ 3. Does this person�rm possess a skill not normall y possessed by any curtent city employee? SUPPORTSWHICHCOUNCILOBJECTIVE? YES NO Explain all yes answers on separate sheet entl attach to green sheet INI77ATING PROBLEM, ISSUE, OPP�RTUNIiY (Who, What, Whan. Where, Why): 1.) Substantial interference between new ductwork and existing building's system. 2.) No support for the fire damper. 3.) Air-handling I-IVAC duct controls found to be defective and direct replacement for original parts no longer available. (These controls are on ducts unaf£ected by this work, but these must be adjusted to balance air flow requirements in the changed portions of the :�VAC system.) VANTAGES IF APPROVED: 1.) New ductwork fits into existing available space. 2.) Fire damper will be fully functional and spills in the healt': l.aboratory cannot run down to first floor through duct penetration. 3.) It will be possible to balance system properly so that the clinic rooms will comply with state and federal environmental recommendations and requirements for health safety of employees, patients, and clients. DISADVANTACaES IF APPROVED: None. RECEIVEt ������ �� FEB 2 61997 ��� 1� assZ �;iTY CLERK � ��;������3 ���� ���� _� DISADVANTAGES IF NOT APPROVE�: 1.) ?Juctwork would not fit. 2.) Fire damper would not function and lab spills would. leak into patient rooms and staff areas. 3.) Cor,tpletian o,f the designed and installed work so that health risks to staff and patients would be reduced to acceptable levels cannot be �o3ie;^`^'. TOTAL AMOUNT OFTiiANSACTION $ � O2� SO COST/REVENUE BUDGETED (CIRCLE ONE) � YES � NO FUNDIHGSOUHCE CPI ACTIVI7VNUMBER G95-3T026-0892-00000 FINANCIAL INFOFiMATION: (EXPLAIN) ' � � � �GREACEN CONSULTING ENGIt�ERS PHONE N0. : 612 633 1885 Dec. 20 1996 12:05PM P2 �o � � 58 � � E�vironrndent�l �ys�e�at��s � ' , af Mi�znesota d'rtcor�vrated � 'OAN7RAGiDRS AMp EiSGlNEERS 12-20-96 13ob Wilcox Graecen Cansulting Engineers 919 rifth A�onueld.W., Ste �00 I�Tow Brighton, Mn. 55112 12c: T'ublic FTru2th �3uilding St, Paui, NTttwcsota lacar �ob; Due to uc�'or9een job cnndidons we rEquest tlte following axtras; • • 2. 2. 3 l�ahrir,ate and insta1132 addifSonnl duat, fittin�s eo make duat run above c.eiling. Requested £.xtra $ 3200.00 Consuvc.t concr�;ts� curb nn s000nd iloor t.n accomodato fue dsrnper isc the ffoar. Kcquested Lxwa � Zsa.oO Repl�+cc 29 Vsv cantrdliers as prapased by A�echa�iical Dnttt. ( Cnpy of proposxl attached) 0 � Prafit - �.S le.�. R�quested Exlra Sinaer2�q, ,.� �� , _ % �--�����- r ��� -s-�` Q. IOIIC5 cC: &la{17P,nith) 1371 MAfl6HAl� AYENUG &T, PAUL, MINNEBOTA 68io4 $ 4100.00 � 420A0 $ d300.00 $ 87,50 �....---._ � 4577.50 6 (GiO.} 846•302E ' FAX (B1Rj 648•800R �